TECHNICAL SPECIFICATIONS:

ELECTRICAL LUNAR DT LUNAR PR
Detection technologies:  Dual element PIR + Microwave  Dual element PIR 
Current consumption:  25 mA at 12 VDC  15 mA at 12 VDC 
Supply voltage:  9-16 VDC regulated 9-16 VDC regulated
Alarm contact:  24 VDC, 50mA  24 VDC, 50 mA
Anti-tamper: Normally closed, 24 VDC, 0.5 A  Normally closed, 24 VDC, 0.5 A 
Pulse count: Selectable 1,2 (alternate polarity)  Selectable 1-3 
Temperature comp.: Micropr. control. (patent pending) 
---
RF immunity:  30V/m. up to 1 GHz  30V/m. up to 1 GHz 
Walk test: 3 LEDs 1 LED
PHYSICAL:
Weight: 138.6 G (5 Oz) 112 G (4 Oz)
Size: 135 x 27 mm 135 x 27 mm
 
OPTICAL:
Lens:
Wide angle spherical Fresnel
Coverage:
110 angle, 360 overview
Detection Zones:
3 optical levels, 12 external sectors, 12 middle sectors, 6 internal sectors
ENVIRONMENTAL:
Operating temperature:
0 C to 55 C (32 Fto 131 F)
Storage temperature:
-20 C to 60 C (-4 F to 140 F)
 

©1997 Rokonet Industries. All Rights Reserved