DSC
Power832
Security System

 

Multiple Keypads

four different keypads available
connect up to 8 keypads to a panel
PC5508 standard 8 zone LED keypad
PC5516 standard 16 zone LED keypad
PC5532 standard 32 zone LED keypad
LCD5500 alphanumeric keypad
Zone Expansion
expand from 8 to 32 zones
2 partitions
Hard Wire
PC5108 - 8 zone expansion module
PC5108D - 16 zone expansion module utilizing zone doubling
Wireless
PC5132-900- wireless zone expansion module
connect up to 32 wireless zones
Output Options
up to 4 high current outputs
PC5204
4 output high current power supply module
1 output fully supervised for siren output
up to 8 voltage outputs
PC5208
8 output transistor switch module (50 mA)
Advanced Communications
supports all major formats including SIA and Contact ID
LINKS cellular communication
event initiated personal paging
3 phone numbers, 2 account numbers
Audio Capability
supports central station two way voice and home intercom features
Efficient Installation
 
4 wire communications bus (KEYBUS)
- connect modules up to 1000' (330m) from control panel
- up to 1.5A auxiliary power
- PC5204 - 4 output high current supply module provides up to 1A auxiliary power
- main panel provides up to 500mA auxiliary power
PC5010 Main Control Panel
up to 32 fully programmable zones
8 zones on main control panel (16 with zone doubler option)
hard wire zones and wireless expansion
all zones programmable as burglary or fire
assign zones to one or both partitions
zone options include: End Of Line (EOL) Resistor, Double EOL resistor, Normally closed loops or zone doubling.
24 programmable zone types
2 partitions
most features programmable by partition
32 - 4 or 6 digit access codes assignable to one or both partitions
1 system master code, 2 partition master codes, and 2 duress codes
128 event buffer
all events automatically stored with time and date stamp to buffer
events can be printed on-site, viewed through the LCD keypad or DLS software alarm output
alarm output
bell output - 700mA @ 12Vdc, PTC protected
additional supervised siren output using PC5204 power supply module, 1A @12Vdc, PTC protected
programmable voltage outputs
main panel PGM2 - high current switch to ground (can also be used for 2 wire smoke)
main panel PGM1 - low current, 50mA@12Vdc
additional low current voltage outputs using PC5208 output module, 50mA@12Vdc
additional high current voltage outputs using PC5204 power supply module, 1.0A@12Vdc
upload/download capability
program system using DLS software
view status and trouble conditions
view 128 event buffer
power capability
500mA@12.5Vdc (400mA for UL applications)
separately fused battery and bell output
positive temperature coefficient (PTC) AUX & Bell output protection
electronic protection of KEYBUS
supervision of AC power loss, low battery, auxiliary power failure
battery required
12V, 4Ah, rechargeable gel-cell
transformer required
16.5Vac, 40VA
System Operation
 
up to 2 partitions
each partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features.
32 access codes
each partition can have any number of user codes which may be enabled to work on one or both partitions
programmable system access by user code
individual open/close reporting by user
automatic arming by partition
each partition may be programmed to auto-arm at different times
'quick arm' and 'quick exit'
allows users to arm and exit easily
Home-Away zones and At-Home arming
security of perimeter arming while premise is occupied
door chime
programmable by zone
monitor a door by having keypad beep when the door is opened and closed


False Alarm Prevention Features
audible exit delay
audible exit failure
programmable swinger shut down by zone
programmable transmission delay by zone
opening after alarm transmission
Full Supervision

Trouble conditions are displayed on all keypads and can also be communicated to central station for:
low battery
loss of AC
auxiliary power failure
zone tamper
siren circuit trouble
fire circuit trouble
buffer near full capacity
failure to communicate
telephone line trouble (via Links cellular communicator)
KEYBUS module communication failure
PC5204 power supply module low battery
PC5204 power supply module AC power loss


Plain Language Interfaces

LCD5500 Keypad

The Power 832 security system is fully programmable from the attractive, easy to use multi-language LCD5500 keypad:
multi-language : English, French, Spanish
simple key entry to toggle between languages while viewing keypad
large 32 character display
zone identification
system instructions
system status
128 event buffer
trouble conditions
plain language operating instructions
menu for user functions
what key to press for specific functions
steps for programming functions
5 programmable function keys with 18 options such as Home Arm, Away Arm, Quick Exit, etc. connect up to 8 keypads, combination LED and/or LCD any keypad can be assigned as 'Global' for system wide control or 'Partition' for operation of a specific partition only 3 LED indicators: Ready, Armed and Trouble
allows system status to be viewed at a glance
4 keypad activated alarms: Panic, Emergency, Fire and Duress backlit display
display and keys backlit for easy viewing in low light conditions
piezo buzzer
provides audible feedback for correct key entries, pre-alert, and system trouble status
specifications
current draw - 50mA
dimensions - 5.75" x 4.5" x 1" deep (144 x 114 x 25mm)


LED Keypads

The Power 832 system is fully programmable from any of the attractive, easy to use, LED keypads:
8 zone, 16 zone and 32 zone keypads
keypads have 5 programmable function keys with 18 options such as home arm, away arm, quick exit, etc.
connect up to 8 keypads, combination LED and/or LCD
any keypad can be assigned as 'Global' for system wide control or 'Partition' for specific partition only
3 LED indicators: Ready, Armed, Status
allows system status to be viewed at a glance
4 keypad activated alarms: Panic, Emergency, Fire and Duress backlit display for easy viewing in low light conditions piezo buzzer
provides audible feedback for correct key entries, pre-alert, and system trouble status
current draw :  50mA


ESCORT 5580 Voice Prompt Module with Automation/Lighting Control
turns any touch-tone phone into a fully functional keypad
built-in power line interface for X-10 control devices
connect up to 32 X-10 devices
options include - 'Global' or 'Partition' control
16 schedules, 8 modes
customized commands
module contains extensive library of voice prompts
program up to 6 words per label
180 pre-programmed system words
241 pre-programmed library words
PC5908 Audio Interface Module with
PC5901 Series Intercom Stations
PC5901 . . . internal intercom station
PC5901EXT . . . external intercom station
PC5901EXT/R . . . external intercom station with relay for operation of existing door bell
PC5908 Audio Interface Module
provides 7 output ports for connection of PC5901 Series Intercom Stations
Local Intercom
page/answer - do not disturb
doorbell function
Listen-in Broadcast . . . allows any station to be a "broadcast station" that may be listened into by all other internal stations in the system Answer Telephone Calls Received on Regular Voice Line
supports call waiting
allows call transfer to in-house phones
Audio User Help
provides plain language prompts for system programming, operation, and system status reports when installed with Escort 5580 Voice Prompt Module and Keypads mounted with PC5901 Intercom Stations
Central Station 2-Way Listen In
programmable control tones (from central station)
select zone, listen/talk, extend on-line time, hang up
PC5400 - RS232
Serial Printer Interface Module
allows serial printer connection for report of events logged to the PC5010 event buffer
supports any 300, 1200, 2400 or 4800 BPS serial printer
multiple connects up to 4 wire KEYBUS up to 1000' (330m) from control panel
c/w DB-25 modular connector for easy connection
current draw : 30mA
maximum one module per station
Zone Expansion Modules
Hard Wire PC5108 - 8 Zone Expander
                 PC5108D - 16 Zone Expander (used with Zone Doubler Feature)
connect modules up to 1000' (330m) from control panel via KEYBUS
assign zones to one or both partitions
25 programmable zone types
Wireless PC5132-900-32 Zone Expander
connect modules up to 1000' (330m) from control panel via KEYBUS
connect up to 32 Marquis devices
true 'Spread Spectrum' technology, 900MHz, fully supervised for communication integrity
12 minute supervisory time
easy sensor enroll process
standard AA/AAA alkaline batteries, 24 to 36 month life
Power / Output Modules
PC5204 Power Supply and 4 High Current Voltage Output Module
provides 1A @ 12.5 Vdc for additional modules, device and siren outputs
includes 4 fully programmable high current outputs
rated at 1A @ 12Vdc, PTC protected
each output programmable to activate for any of 18 options one output fully supervised for siren connection connect modules up to 1000' (330m) from control panel via KEYBUS fully supervised for low battery and AC power loss maximum 1 module per system PC5208 Low Current Output Module
module provides 8 low current transistor switch outputs
rated at 50mA @ 12.5Vdc
each output programmable to activate for any of 18 options connect modules up to 1000' (330m) from control panel via KEYBUS fully supervised for low battery and AC power loss maximum 1 module per system Architects Specification
.....................................................................

The contractor shall provide a complete electrically supervised, battery backed-up, fire and burglary alarm system.  The system shall be complete with a multi-zone alarm system with the capability of expansion up to 32 burglar or class B fire zones of which up to 32 may be wireless zones.  All zones shall be supervised and be capable of operating listed heat detectors, smoke detectors and other listed fire and burglary alarm detection devices.  The system shall have expansion capability for up to eight low current transistor switch outputs; and 4 high current outputs of which one may be fully supervised for an additional siren.  All outputs shall be programmable as 1 of 18 types.  System shall be complete with a 4 wire unshielded (QUAD) communications bus that allows expansion modules for zones and outputs to be added anywhere on the bus up to 1000'  (330m) per leg from the main control panel.  The system shall be capable of providing up to 1.5 amps of 12.5Vdc auxiliary power for alarm devices.

The system shall be complete with a built-in power line interface for up to 32 X-10 control devices.

The alarm panel shall be complete with an integrated digital communicator capable of being programmed to transmit to three separate monitoring stations or locations with 2 account numbers.  The communicator shall be capable of supervising the telephone line; and shall support and supervise LINKS cellular communication with three telephone numbers for backup or sole communications to monitoring stations and for upload download operations.  The system communicator shall be capable of communicating in all major formats including SIA and Contact ID.  Events transmitted shall be programmable to include: fire alarms, burglary alarms, trouble alarms, supervisory conditions, alarm restoral codes, opening (disarming) and closing (arming) codes, partial closing codes, and opening after alarm codes. The system shall be capable of paging personnel on the occurrence of any of the above events selected by the owner.  The system shall be capable of transmitting a test code to the monitoring station(s) on a programmable daily, weekly, or monthly frequency at a regular time of day.

The system shall be complete with audio interface capable of supporting up to 7 audio ports for local intercom/paging, listen-in broadcast, telephone answering, audio user help, and 2-way listen-in by the monitoring station.

There shall be a 700mA, PTC protected, supervised bell/siren circuit that will drive a bell/siren until reset or silenced.  Siren output shall be programmable as steady or pulsed for each zone.

The alarm shall be equipped with EEPROM memory to retain all program information even if all AC and battery power is lost and shall have integral static and lighting protection circuitry.

The alarm panel shall have SIA false alarm prevention features, programmable swinger shut down by zone, programmable transmission delay buy zone, audible exit delay, audible exit fault, opening after alarm reporting, and 'quick exit' to prevent false alarms and unnecessary transmissions to monitoring stations.

The system shall allow up to 2 'partitions' each acting as a separate alarm system with its own zones, siren output, user codes and keypads for programming, arming and disarming.  Each partition shall be programmable to Auto-Arm at different times on every day of the week.

The system shall have home-away and at-home arming capability to allow the user to remain on the premises while system is armed.  A quick-arm feature shall allow users without access codes to arm the system and exit.  A door chime feature shall cause the keypad to beep when a selected door in a partition is opened or secured.

The system shall support any combination of up to 8 "Multi-Language" or "LED" type keypads with backlit displays.  Keypads shall be surface mounted and capable of fully programming and operating the system.  Each keypad shall be assignable to operate the entire system or an individual partition.  Multi-Language keypads shall be complete with 32 character liquid crystal display (LCD) to provide plain language programming instructions, operating instructions and display of all alarms and supervisory conditions.  They shall be capable of toggling between English, French and Spanish by pressing a key combination on keypad.  LED keypads shall have 6, 16 or 32 zone indicators as required.  All keypads shall have keypad activated emergency alarms for panic, emergency, fire and duress; LED indicators for Ready, Armed and Trouble or Status; and shall be equipped with a Piezo Buzzer to provide audible feedback for correct key entries, pre-alert, and trouble.

The system shall allow any touch-tone phone to be used as a keypad with programmable voice prompts for system commands, functions, and labels (zones, etc.)

The system shall allow 32 - 4 or 6 digit - user codes which may be assigned to one or multiple partitions.  The system shall accommodate 1-system master code, 2-partition master codes, and 2-duress codes.

The system shall be uploadable/downloadable to allow programming and operation from a remote computer over a telephone line or LINKS cellular communications equipment.  Remote access shall be controlled by the owner to prevent unauthorized access.

The system shall support a 300, 1200, 2400 or 4800 baud serial printer connected to the communications BUS up to 1000' (330m) from the control panel.  The printer shall log all system events and transactions with time and date stamp.  Information shall be stored in the systems 128 event buffer which may be examined from the LCD keypad or the DLS software.

The system shall meet UL standards as required for type of application.
 